image

Circular Electromagnetic Chuck

Magnetic Chucks for Grinding Operations

Circular Electromagnetic Chuck

Application

Circular electromagnetic chucks are designed for rotary grinding machines and generate strong magnetic force to hold ferrous workpieces rigidly.

The chuck operates on continuous D.C. power. Its electromagnetic construction avoids internal mechanical movement and associated wear, supporting reliable, long-life workholding.

Pole Configuration

The circular magnetic face has a 4 mm pole gap and 14 mm pole pitch across all available models.

Construction & Characteristics

  • Designed for rotary grinding machines and circular workholding.
  • Strong electromagnetic force holds ferrous workpieces rigidly.
  • Continuous D.C. operation provides consistent magnetic holding.
  • 4 mm pole gap with 14 mm pole pitch.

Characteristics of Control Panel

  • Input power supply: 230 V A.C.
  • Output operating voltage: 110 V D.C.
  • A.C. and D.C. supplies protected by fuses and MCB.
  • Indicators for main supply, Magnet ON and demagnetizing cycle.

Inspection & Accessories

Inspection tests:
1) Resistance-to-earth terminal test
2) Demagnetizing test
3) High-voltage test
4) Leak-proof test
5) Slipping-force test as per IS 8710-1978

D.C. Power Supply UnitMag/Demag UnitOperating Pendant

Designed for Safe & Reliable Operation

Circular Electromagnetic Chucks operate on a continuous D.C. power supply and require an external power supply arrangement. The control panel incorporates electrical safety provisions using fuses on the A.C. and D.C. supply circuits along with MCB protection.

Control Requirement

A D.C. power-supply unit or Mag/Demag unit is required to operate the circular chuck.

Inspection & Safety Tests

  1. Check resistance to earth terminal before operation.
  2. Carry out the de-magnetizing test to verify proper release of the workpiece.
  3. Perform the high-voltage test as part of electrical inspection.
  4. Carry out the leak-proof test to verify the condition of the chuck.
  5. Perform the sleeping-force test as per IS 8710-1978.
  6. Use the specified continuous D.C. power supply for operating the chuck.
  7. Ensure appropriate fuse and MCB protection is provided for the A.C. and D.C. supply circuits.

Operation Sequence (Follow the steps)

01

Connect the chuck to the D.C. power-supply or Mag/Demag control unit.

02

Clean the circular chuck surface and ferrous workpiece contact face.

03

Position the workpiece correctly on the circular magnetic face.

04

Switch Magnet ON using the operating pendant.

05

Confirm rigid magnetic holding before starting rotary grinding.

06

Perform rotary grinding while maintaining continuous D.C. supply.

07

Stop the machine and initiate the demagnetizing cycle after grinding.

08

Remove the workpiece only after demagnetization is complete.

Available Sizes

Circular electromagnetic chuck dimensions are specified by chuck diameter, height, pole gap and pole pitch.

Model Code Size (Dia. × H) Pole Gap Pole Pitch
002-05-01 Dia. 300 × 100 mm 4 mm 14 mm
002-05-02 Dia. 400 × 100 mm 4 mm 14 mm
002-05-03 Dia. 600 × 100 mm 4 mm 14 mm
002-05-04 Dia. 750 × 125 mm 4 mm 14 mm
002-05-05 Dia. 1000 × 125 mm 4 mm 14 mm
002-05-06 Dia. 1200 × 125 mm 4 mm 14 mm

Applications

Mag Demag unit with pendant for circular electromagnetic chuck
Magnetizing & Demagnetizing Unit with Pendant

A D.C. power-supply unit or Mag/Demag unit is required for operating the circular electromagnetic chuck.

WhatsApp
Call Us